Skip to content
AMPORYUnited States

Sources

References support only the claims and conditions listed here. A verified unit factor does not verify an entire calculator or an installation. Numerical example checks, documentary review and data reuse rights are separate.

  • Guide for the Use of the International System of Units (SI), Appendix B.8

    NIST · SP 811, 2008 edition (web tables) · VERIFIED

    Reviewed scope: International length, mechanical horsepower and customary area factors; SI conversion basis

    Conversion factors only; legacy source ID is retained and does not denote a 2024 edition. Use separate temperature-interval and absolute-temperature formulas.

    Section: Alphabetic conversion factors; SP 811 version history. Reuse status: ALLOWED_PUBLIC. Checked 2026-11-24.

  • University Physics Volume 2, 9.5 Electrical Energy and Power

    OpenStax · Online edition; revision not stated · VERIFIED

    Reviewed scope: P=IV; resistor dissipation; energy as power integrated over time

    DC/resistive and ideal energy accounting; efficiency and capacity factors are user assumptions, not battery discharge curves.

    Section: Equations 9.12–9.13 and energy/cost examples. Reuse status: ALLOWED_CITATION_ONLY. Checked 2026-11-24.

  • IEC 60909-0 — Short-circuit currents (peak factor κ)

    IEC · · BLOCKED_ACCESS

    Reviewed scope: Peak-factor documentary verification pending

    Full IEC text not reproduced; user-supplied impedances only

    Section: Full clause not accessed; engine comment is not documentary evidence. Reuse status: BLOCKED_LICENSE. Checked 2026-11-24.

  • NFPA 70 National Electrical Code

    NFPA · 2023 · BLOCKED_LICENSE

    Reviewed scope: Product landing page only — ampacity/fill tables not copied

    No table embed without NFPA license; jurisdiction-specific adoption

    Section: Not body-verified in US-4. Reuse status: BLOCKED_LICENSE. Checked 2026-11-24.

  • University Physics Volume 2, 15.4 Power in an AC Circuit

    OpenStax · Online edition; revision not stated · VERIFIED

    Reviewed scope: Sinusoidal RMS real power P=VI cosφ; resistor I²R loss

    Single-phase sinusoidal AC; this section does not itself establish three-phase √3 relations.

    Section: Equations 15.12–15.14. Reuse status: ALLOWED_CITATION_ONLY. Checked 2026-11-24.

  • Copper Wire Tables, Circular of the Bureau of Standards No. 31

    NBS (now NIST) · Second edition · VERIFIED

    Reviewed scope: AWG endpoints and 39-step diameter progression; nominal area derived from circular geometry

    Bare nominal geometry only; no insulation diameter, ampacity or substitution approval. Circular-mil area is derived using the mil length definition.

    Section: PDF page 25: characteristics of American Wire Gage; nominal sizes and geometric progression. Reuse status: ALLOWED_PUBLIC. Checked 2026-11-24.

  • 29 CFR 1910.147 — The control of hazardous energy

    OSHA · 29 CFR 1910 Subpart J · VERIFIED

    Reviewed scope: Machine servicing hazardous-energy control and distinction from electrical utilization hazards under Subpart S

    This section is not a blanket substitute for 1910.333; construction, agriculture, utilities and other listed exclusions have separate scope.

    Section: 1910.147(a)(1)(i)–(ii), especially electrical-hazard exclusion (D). Reuse status: ALLOWED_PUBLIC. Checked 2026-11-24.

  • IEEE Std 141 (Brown Book) — commercial building power

    IEEE · · PENDING

    Reviewed scope: Voltage system naming 208Y/120, 480Y/277 discussed in industry practice

    Full standard not body-verified; guide stays educational

    Section: Landing / scope only (full text not verified in US-5). Reuse status: BLOCKED_LICENSE. Checked 2026-11-24.

  • 29 CFR 1910.399 — Definitions applicable to Subpart S

    OSHA · 29 CFR 1910 Subpart S · VERIFIED

    Reviewed scope: Conceptual distinction between conductive bonding, connection to earth, and equipment grounding functions

    Terminology scope only; no NEC conductor sizing or electrode design verified.

    Section: Bonding; grounded; grounding conductor definitions. Reuse status: ALLOWED_PUBLIC. Checked 2026-11-24.

  • Explicit mathematical definitions used by Ampory

    Ampory · Online edition; revision not stated · NOT_APPLICABLE

    Reviewed scope: Ratios, sums, differences, area fractions and user-defined scheduling arithmetic

    Pure arithmetic is independently checked; this is not external technical or regulatory approval.

    Section: Site formula definitions; not an external standard. Reuse status: USER_INPUT_ONLY. Checked 2026-11-24.

  • IEC inverse-time relay curve coefficients

    IEC / manufacturer · Online edition; revision not stated · PENDING

    Reviewed scope: SI coefficient and time multiplier documentary review pending

    No full standard or licensed table was accessed.

    Section: Not body-verified. Reuse status: UNKNOWN. Checked 2026-11-24.

  • University Physics Volume 2, 9.4 Ohm’s Law

    OpenStax · Online edition; revision not stated · VERIFIED

    Reviewed scope: Voltage/current proportionality for ohmic elements

    Temperature and operating point can change resistance; non-ohmic devices excluded.

    Section: Ohmic relation and scope of linear materials. Reuse status: ALLOWED_CITATION_ONLY. Checked 2026-11-24.

  • 29 CFR 1910.333 — Selection and use of work practices

    OSHA · 29 CFR 1910 Subpart S · VERIFIED

    Reviewed scope: Deenergization, electrical lockout/tagging and qualified-person verification; restricted energized-work conditions

    Covered general-industry utilization installations; exceptions and other workplace standards need employer review. Not a field procedure.

    Section: 1910.333(a)(1)–(2), (b)(1), (b)(2)(iv), (c)(2). Reuse status: ALLOWED_PUBLIC. Checked 2026-11-24.

  • DOE Fundamentals Handbook, Electrical Science Volume 3

    U.S. Department of Energy · DOE-HDBK-1011/3-92 Rev. 0 · VERIFIED

    Reviewed scope: RMS P/Q/S relationships and balanced line-voltage/current power relations

    Balanced sinusoidal fundamentals; efficiency conversion and user margins are explicit algebraic assumptions, not equipment selection standards.

    Section: Module ES-09 Power Triangle; Three-Phase Circuits, PDF pages 67–91. Reuse status: ALLOWED_PUBLIC. Checked 2026-11-24.

  • DOE Fundamentals Handbook, Electrical Science Volume 4

    U.S. Department of Energy · DOE-HDBK-1011/4-92 Rev. 0 · VERIFIED

    Reviewed scope: Synchronous speed and slip; ideal transformer ratios and output/input efficiency

    Ideal or simplified steady-state relationships; no instrument transformer burden class, insulation rating or parallel-operation approval.

    Section: ES-12 equations 12-1/12-2 PDF page 25; ES-13 voltage/current ratio and losses, PDF pages 49–56. Reuse status: ALLOWED_PUBLIC. Checked 2026-11-24.

  • University Physics Volume 2, 15.3 RLC Series Circuits with AC

    OpenStax · Online edition; revision not stated · VERIFIED

    Reviewed scope: Series RLC impedance magnitude and phase relationships

    Lumped linear sinusoidal circuit; cable material constants and empirical detuning practice are separate claims.

    Section: Equations 15.10–15.11; phasor diagram. Reuse status: ALLOWED_CITATION_ONLY. Checked 2026-11-24.

  • University Physics Volume 2, 9.3 Resistivity and Resistance

    OpenStax · Online edition; revision not stated · VERIFIED

    Reviewed scope: R=ρL/A and local linear temperature dependence of resistance

    Material coefficients are sample-dependent; this does not verify every coefficient or a wide-temperature validity range.

    Section: Resistance from conductor geometry; temperature dependence. Reuse status: ALLOWED_CITATION_ONLY. Checked 2026-11-24.

  • University Physics Volume 1, 10.7 Newton’s Second Law for Rotation

    OpenStax · Online edition; revision not stated · VERIFIED

    Reviewed scope: Net torque equals moment of inertia times angular acceleration

    Constant inertia and average net accelerating torque; integration to time assumes starting at rest.

    Section: Fixed-axis torque/angular acceleration derivation. Reuse status: ALLOWED_CITATION_ONLY. Checked 2026-11-24.

  • NIST/SEMATECH e-Handbook of Statistical Methods — Measures of Location

    NIST · Online edition; revision not stated · VERIFIED

    Reviewed scope: Arithmetic mean of a finite sample

    No regression or anomaly classification is established by a mean alone.

    Section: 1.3.5.1 definition of arithmetic mean. Reuse status: ALLOWED_PUBLIC. Checked 2026-11-24.

  • NIST/SEMATECH e-Handbook of Statistical Methods — Measures of Scale

    NIST · Online edition; revision not stated · VERIFIED

    Reviewed scope: Sample variance uses n−1; standard deviation and range definitions

    At least two observations for sample standard deviation; no uncertainty accreditation or compliance conclusion.

    Section: 1.3.5.6 sample variance, standard deviation and range. Reuse status: ALLOWED_PUBLIC. Checked 2026-11-24.