Trend statistics
Summarize a pasted numeric series with mean, minimum, maximum, range, sample standard deviation and first-to-last percentage change.
Paste numeric samples. Optional ISO timestamps in the first column.
Calculator overview
Summarize a pasted numeric series with mean, minimum, maximum, range, sample standard deviation and first-to-last percentage change.
How to use
- Paste one numeric observation per line, or timestamp/value rows in the documented format.
- Choose display precision and select Analyze trend.
- Review descriptive statistics for the supplied data. Invalid data rows are reported rather than silently discarded.
Formula
Mean, min, max, sample standard deviation, percent change
- x_i (user) — Samples
Worked example
Worked example: trend analysis
Inputs: raw = 100; 102; 101; 99; 103. Mean = Σx/n = 505/5; sample SD = √(10/4). Expected avg = 101 input units. Display precision may round this value.
Expect key result avg to contain 101 when you run the calculator with the same inputs.
Understanding the results
These are descriptive sample statistics. There is no regression fit, forecast, unit selector or export workflow. Sample standard deviation requires at least two observations.
Practical applications
Facility O&M, ECM verification prep.
Common mistakes
Combining different physical units or sampling windows, interpreting first-to-last change as a fitted slope, or using one observation to estimate sample variation.
Limitations
No root-cause analysis, forecast, anomaly threshold, time-series storage or meter uncertainty model.
Results are engineering estimates only. They are not NEC compliance, arc-flash studies, or licensed design deliverables.
References
- Guide for the Use of the International System of Units (SI), Appendix B.8(verified)
International length, mechanical horsepower and customary area factors; SI conversion basis. Conversion factors only; legacy source ID is retained and does not denote a 2024 edition. Use separate temperature-interval and absolute-temperature formulas.
- NIST/SEMATECH e-Handbook of Statistical Methods — Measures of Location(verified)
Arithmetic mean of a finite sample. No regression or anomaly classification is established by a mean alone.
- NIST/SEMATECH e-Handbook of Statistical Methods — Measures of Scale(verified)
Sample variance uses n−1; standard deviation and range definitions. At least two observations for sample standard deviation; no uncertainty accreditation or compliance conclusion.
FAQ
- Does the tool fit a trend line?
- No. It reports descriptive statistics and first-to-last change.
- Can I mix kW and kWh rows?
- No. Every observation must use the same quantity and measurement basis.
- Why is standard deviation unavailable for one point?
- The sample estimator uses an n−1 denominator and needs at least two observations.