RLC Impedance Calculator

Analyzes series RLC (and RL, RC, LC subsets) circuits at a sinusoidal frequency: reactances XL and XC, net X, magnitude |Z|, phase angle, power factor, current, and optional resonance. Built for troubleshooting power-factor anomalies, studying detuning, and validating instrument math—not for substation protection studies.

Steady-state sinusoidal series circuit. No parallel topology, tolerance, or transient response. 0 Hz with capacitance and 0 F are rejected.

Enter values and calculate.

Calculator overview

Analyzes series RLC (and RL, RC, LC subsets) circuits at a sinusoidal frequency: reactances XL and XC, net X, magnitude |Z|, phase angle, power factor, current, and optional resonance. Built for troubleshooting power-factor anomalies, studying detuning, and validating instrument math—not for substation protection studies.

How to use

  1. Pick the circuit type (R, L, C, RL, RC, LC, RLC) matching your schematic—only series topologies modeled.
  2. Enter R, L, and C with correct unit selectors (Ω, mH, μF, etc.); open branches should be omitted via circuit type.
  3. Enter frequency in Hz (60 Hz for most US industrial power) and RMS voltage.
  4. Read |Z|, phase angle (inductive +, capacitive −), PF = R/|Z|, and I = V/|Z|.
  5. Note resonance frequency f₀ = 1/(2π√(LC)) when both L and C are present.
  6. Use the impedance-vs-frequency sweep in the UI to see how |Z| moves toward f₀.

Formula

XL=2πfL; XC=1/(2πfC); X=XL−XC; Z=R+jX; |Z|=√(R²+X²); PF=R/|Z|; I=V/|Z|; P=I²R; Q=I²X; S=VI; f0=1/(2π√LC)

  • R (Ω) — Only elements in the selected circuit
  • L (H) — Converted to SI units before calculation
  • C (F) — Positive when present in the circuit
  • V (V) — Voltage

Worked example

Worked example: rlc impedance

Inputs: circuit = RLC, r = 10, l = 100, c = 100, frequency = 60, voltage = 208, rUnit = Ω, lUnit = mH, cUnit = μF, frequencyUnit = Hz, voltageUnit = V. |Z| = √(R²+(ωL−1/(ωC))²). Expected z = 14.994745 Ω. Display precision may round this value.

Expect key result z to contain 14.994745 when you run the calculator with the same inputs.

Understanding the results

Capacitive reactance falls and inductive reactance rises with frequency; near f₀, |X| is small and |Z| approaches R, so current is highest limited by resistance and source impedance not modeled here. Ideal LC resonance at R=0 is singular—real branches always have some R. Q is not a compliance metric in this tool.

Practical applications

Explaining uncorrected power factor on capacitor banks, estimating current in filter branches, teaching vector addition of R and jX, correlating DMM/FRA readings with textbook math before field tuning.

Common mistakes

Treating parallel loads as series RLC, forgetting to convert mH/μF, using peak voltage instead of RMS, ignoring source impedance so measured current is lower than V/|Z|, and assuming resonance implies unlimited current with real wire resistance.

Limitations

Series only; no mutual coupling, skin effect tables, core losses, or nonsinusoidal sources. Harmonic penetration needs THD tools, not single-frequency |Z|.

Results are engineering estimates only. They are not NEC compliance, arc-flash studies, or licensed design deliverables.

References

FAQ

Why is PF less than 1 with resistance present?
Reactive energy storage rotates current out of phase with voltage even when R dissipates real power.
Above or below resonance at 60 Hz?
Compare f to f₀: below f₀ net reactance is capacitive (current leads); above f₀ it is inductive for series RLC.
Does this size capacitor banks?
Use power-factor-correction for kvar targets; this tool shows branch impedance physics.
208 V vs 240 V in examples?
Voltage scales current linearly if impedance is unchanged—use your actual service voltage.
Parallel RL loads?
Not modeled—circuit type must match a series path.

Analyzes series RLC (and RL, RC, LC subsets) circuits at a sinusoidal frequency: reactances XL and XC, net X, magnitude |Z|, phase angle, power factor, current,