Electrical calculators
Choose a calculation
Use the voltage across the actual load and distinguish nominal conductor area from insulated outside diameter. Read the formula and limitations for each tool.
- Single-phase load current calculator
Estimates single-phase line current from real power, voltage, power factor, and optional efficiency. Use for branch load checks and nameplate comparisons—not NEC ampacity selection.
- Three-phase load current calculator
Calculates balanced three-phase line current from kW, line-to-line voltage, power factor, and efficiency.
- Current to power calculator
Estimate real electrical power in kW from line current, load voltage and power factor for a two-wire single-phase or balanced three-phase circuit.
- kW / kVA / HP converter
Convert a known kW, kVA or horsepower quantity using the supplied power factor and the shared rounded 746 W per mechanical HP convention.
- Power factor calculator
Computes power factor from kW and kVA or related inputs per the form layout.
- kW kVAR kVA triangle
Constructs kW–kvar–kVA relationships and phase angle for visualization and field checks.
- Power factor correction
Estimates kvar and approximate current change to reach a target power factor.
- Motor slip and synchronous speed
Relates synchronous speed, measured rpm, and slip for induction machines.
- Motor acceleration time
Estimate acceleration time from rest using total referred inertia, target rpm and constant average net accelerating torque.
- Transformer capacity and load ratio calculator
Relates transformer kVA rating, load kW/kVA, and load percent for loading assessments.
- Transformer rated current
Calculates three-phase rated line currents on primary and secondary sides from nameplate kVA and line-to-line voltages: I = S / (√3 × V). Results support cable sizing discussions, metering CT planning, and procurement checks—they are not short-circuit duty, tap-compensated protection, or substation relay settings.
- Transformer losses
Estimates no-load and load losses and efficiency from nameplate loss data and loading.
- RLC Impedance Calculator
Analyzes series RLC (and RL, RC, LC subsets) circuits at a sinusoidal frequency: reactances XL and XC, net X, magnitude |Z|, phase angle, power factor, current, and optional resonance. Built for troubleshooting power-factor anomalies, studying detuning, and validating instrument math—not for substation protection studies.
- CT ratio
Converts between primary amps and secondary amps for instrument CT ratios.
- PT VT ratio
Calculate an ideal PT/VT voltage ratio from rated primary and secondary voltages.
- Busbar review
Calculate total rectangular busbar metal area, current density and an optional user-supplied current-density comparison.
- Lighting power density
Compute connected lighting input watts per square meter, with an optional arithmetic comparison to previous wattage and operating hours.
- Motor Running Current Calculator
Estimate balanced three-phase motor current from shaft power, line-to-line voltage, running power factor and efficiency. Mechanical hp converts to watts before the shared current engine runs.
- Ohm's Law Calculator
Ohm’s law and DC power for a passive resistive element: solve for V, I, R, or P from any two independent positives.
- AWG / mm² / kcmil Converter
Convert between AWG, kcmil, circular mil, and mm² using nominal cross-section definitions used for communication — not ampacity.
- Contract power to current
Convert a stated electrical demand into current at 480 V three-phase or 120 V single-phase. Not a utility service classification or NEC Article 220 load study.
- Cable ampacity review
Multiply a user-supplied table ampacity and correction factors, then compare with your design current. The site does not ship NEC Table 310.16.
- Conduit Fill — Physical Area Calculator
Physical raceway fill using insulated conductor cross-sectional areas you supply. No NEC Chapter 9 table is embedded.