Calculators
Equipment runtime ratio
Summarize operating-time ratio, starts per hour and average on/off durations from an observation interval.
Calculator overview
Summarize operating-time ratio, starts per hour and average on/off durations from an observation interval.
How to use
- Enter total observation hours and on-hours within that interval.
- Optionally enter off-hours and the number of starts.
- Read on-hours divided by observation hours, starts per hour and average durations when defined.
Formula
Runtime = t_on / t_period
- t_on (h) — See the Formula section and worked example for calculation steps.
Worked example
Worked example: duty cycle
Inputs: periodHours = 24, onHours = 12, offHours = 12, starts = 6. Runtime ratio = ON/observation × 100; no average-current calculation. Expected rt = 50 %. Display precision may round this value.
Expect key result rt to contain 50 when you run the calculator with the same inputs.
Understanding the results
These are operating-time statistics. The form does not accept load current and does not calculate an equivalent thermal current or energy.
Practical applications
Crane hoists, compressors, cyclical process loads.
Common mistakes
Confusing runtime ratio with an IEC motor duty class, using cycle hours instead of the full observation interval, or entering more on-hours than observation hours.
Limitations
No average load, thermal time constant, IEC duty classification or permitted starts-per-hour limit is inferred.
Results are engineering estimates only. They are not NEC compliance, arc-flash studies, or licensed design deliverables.
References
- Guide for the Use of the International System of Units (SI), Appendix B.8(verified)
International length, mechanical horsepower and customary area factors; SI conversion basis. Conversion factors only; legacy source ID is retained and does not denote a 2024 edition. Use separate temperature-interval and absolute-temperature formulas.
- University Physics Volume 2, 9.5 Electrical Energy and Power(verified)
P=IV; resistor dissipation; energy as power integrated over time. DC/resistive and ideal energy accounting; efficiency and capacity factors are user assumptions, not battery discharge curves.
- Explicit mathematical definitions used by Ampory(pending)
Ratios, sums, differences, area fractions and user-defined scheduling arithmetic. Pure arithmetic is independently checked; this is not external technical or regulatory approval.
FAQ
- What if off-hours are blank?
- The engine uses observation hours minus on-hours.
- Does 50% runtime mean half the heating?
- No. Current, starting losses and thermal behavior are outside this time-ratio model.
- What if no starts are recorded?
- Starts per hour is zero and per-start average durations are omitted.